The CloudEngine S6730-H-V2 series offers a range of next generation 10 GE routing switches with 24, 28, or 48 downlink ports plus 6 x 40 GE uplink ports — which can be expanded to 100 GE through licensing — and one extended slot.
Built on Huawei's unified software platform , the series offers a range of various Intent-Driven Network (IDN) features, including support for Virtual Extensible Local Area Network (VXLAN) technology, which builds one network for multiple purposes. Meanwhile, a free mobility feature ensures a consistent user experience.
The S6730-H28X6CZ-V2 is a next-generation enterprise-class core and aggregation switch designed to meet the evolving demands of modern networks. Part of Huawei's CloudEngine S6730-H-V2 series, this switch offers high performance, flexibility, and advanced features suitable for various networking scenarios.
The S6730-H28X6CZ-V2 boasts several notable features:
▪ High Port Density: Equipped with 28 x 10 GE SFP+ downlink ports and 6 x 40/100 GE QSFP28 uplink ports, providing ample connectivity options.
▪ Flexible Uplink Ports: Default 40 Gbit/s uplink ports can be upgraded to 100 GE through licensing, allowing for scalable network growth.
▪ Advanced VXLAN Support: Supports Virtual Extensible LAN (VXLAN) for network virtualization, enabling the creation of multiple virtual networks over a physical infrastructure.
▪ High Switching Capacity: Offers a switching capacity of up to 2.4 Tbps, ensuring efficient data forwarding and minimal latency.
▪ Redundant Power Supply: Features dual pluggable power modules with 1+1 redundancy, enhancing system reliability.
▪ Intelligent Stack (iStack): Supports iStack technology, allowing multiple switches to function as a single logical device for simplified management and enhanced scalability.
▪ Comprehensive Security Features: Includes various security mechanisms such as 802.1X authentication, MAC address filtering, and port security to safeguard network integrity.
▪ Energy Efficiency: Designed with energy-saving features to reduce power consumption without compromising performance.
▪ Robust Quality of Service (QoS): Provides advanced QoS capabilities to prioritize critical traffic and ensure optimal performance for essential applications.
▪ Enhanced O&M: Offers intelligent operations and maintenance features, including real-time monitoring and diagnostics, to simplify network management.
Below are the key technical specifications of the S6730-H28X6CZ-V2:Fixed Ports:28 x 10 GE SFP+
Uplink Ports:6 x 40/100 GE QSFP28
Extended Slots:1 extended slot
Switching Capacity:1.76 Tbps / 2.4 Tbps
Forwarding Performance:490 Mpps
Power Supply:Dual pluggable power modules, 1+1 redundancy
Dimensions (W x D x H):442 mm x 420 mm x 43.6 mm
Weight:7.06 kg
The S6730-H28X6CZ-V2 is versatile and can be deployed in various scenarios:
▪ Enterprise Campus Networks: Serves as a core or aggregation switch, providing high-speed connectivity and advanced features to support large-scale enterprise environments.
▪ Data Centers: Functions as a top-of-rack (ToR) or end-of-row (EoR) switch, offering high-density 10 GE ports and flexible uplink options for efficient data center networking.
▪ Service Provider Networks: Suitable for aggregation and core layers, delivering robust performance and scalability to meet the demands of service provider infrastructures.
The S6730-H28X6CZ-V2 is equipped with advanced networking features to enhance performance and flexibility:
The switch supports VXLAN L2 and L3 gateways, enabling the creation of virtualized networks over a shared physical infrastructure. This capability allows for the segmentation of network resources and supports multi-tenant environments.
With iStack technology, multiple S6730-H28X6CZ-V2 switches can be interconnected to form a single logical device. This simplifies network management and enhances scalability, allowing for seamless network expansion.
The switch offers robust security features, including:▪ 802.1X Authentication: Ensures that only authorized devices can access the network.
▪ MAC Address Filtering: Allows for the control of device access based on MAC addresses.
▪ Port Security: Protects against unauthorized access by limiting the number of valid MAC addresses allowed on a port.
The S6730-H28X6CZ-V2 simplifies network management and maintenance through:
▪ Cloud Management: Supports cloud-managed network services throughout the full lifecycle, from planning and deployment to monitoring and optimization.
▪ Intelligent O&M: Provides real-time monitoring, diagnostics, and analytics to proactively identify and resolve network issues.
▪ Unified User Management: Authenticates both wired and wireless users, ensuring a consistent experience across the network.
Designed with energy efficiency in mind, the S6730-H28X6CZ-V2 incorporates:
▪ Energy-Efficient Ethernet (EEE): Reduces power consumption during periods of low network activity.
▪ Intelligent Fan Control: Adjusts fan speed based on system temperature to minimize energy usage.
▪ Low-Power Components: Utilizes high-efficiency power supplies and components to decrease overall energy consumption.
The S6730-H28X6CZ-V2 provides advanced QoS features to ensure optimal performance for critical applications. It supports traffic classification, queue scheduling, and congestion control to prioritize essential data.
With flexible bandwidth management, network administrators can allocate resources efficiently, ensuring high-priority applications receive the necessary bandwidth while preventing congestion.
The switch minimizes delay with its high-performance forwarding architecture, making it suitable for latency-sensitive applications such as VoIP and video conferencing.
The S6730-H28X6CZ-V2 ensures network reliability with built-in redundancy and failover mechanisms:
▪ 1+1 Redundant Power Supply: Supports hot-swappable power modules for uninterrupted operation.
▪ Intelligent Link Backup: Automatically reroutes traffic in case of link failure to maintain connectivity.
▪ Loop Prevention Mechanisms: Supports STP, RSTP, and MSTP to prevent network loops.
This switch is ideal for a variety of network environments:
▪ Large Enterprises: Provides high-speed connectivity and security for large corporate networks.
▪ Service Providers: Acts as an aggregation or core switch in ISP and carrier networks.
▪ Government and Education: Supports secure and scalable networking solutions for institutions.
The Huawei S6730-H28X6CZ-V2 is a powerful, flexible, and feature-rich switch designed for modern networking needs. Its high-performance switching capacity, advanced security features, and energy-efficient design make it an excellent choice for enterprises, data centers, and service providers looking for a scalable and reliable solution.
Huawei CloudEngine S6730-H Switches
Huawei All Series Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected])
Table 4-27 Basic information about the S6730-H28X6CZ-V2
Item | Details |
---|---|
Description | S6730-H28X6CZ-V2 bundle (28*10GE SFP+ ports, 6*100GE QSFP28 ports, with license, 1*expansion slot, without power module) |
Part Number | 02354VCR |
Model | S6730-H28X6CZ-V2 |
First supported version | V600R022C00 |
Remarks | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
Figure 4-10 S6730-H28X6CZ-V2 appearance
1 | Twenty-eight 10GE SFP+ optical ports | 2 | Six 40GE/100GE QSFP28 optical ports NOTE:By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
3 | One PNP button NOTICE:To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 4 | Ground screw NOTE:It is used with a ground cable. |
5 | Card slot NOTE:In versions earlier than V600R024C00, this card slot is reserved. Applicable card: HSIC-X08S000 (available since V600R024C00 version) | 6 | One USB port |
7 | One ETH management port | 8 | One console port |
9 | Fan module slot 1 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Fan module slot 2 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | Fan module slot 3 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | Power module slot 1 NOTE:Applicable power modules:
|
13 | Power module slot 2 NOTE:Applicable power modules:
| - | - |
Table 4-28 Ports on the S6730-H28X6CZ-V2
Port | Connector Type | Description | Available Components |
---|---|---|---|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE/100GE QSFP28 optical port | QSFP28 | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. In V600R023C10 and later versions, the last two 100GE ports can each be split into four 25GE ports using a command. The port can be automatically converted into four 10GE ports using one-to-four QSFP+ optical modules or AOC optical cables. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
Figure 4-11 Indicators on the switchTable 4-29 Description of indicators on the switch
No. | Indicator | Name | Color | Status | Description |
---|---|---|---|---|---|
1 | SYS | System status indicator | - | Off | The system is not running. |
Green | Fast blinking | The system is starting. | |||
Green | Steady on | During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. | |||
Green | Slow blinking | The system is running normally. | |||
Red | Steady on | A fault that affects services has occurred and it cannot be rectified automatically (critical alarm about hardware). | |||
2 | MST | Stack indicator | - | Off | The switch is not the master switch in a stack. |
Green | Blinking | The switch is the master switch in a stack or a standalone switch. | |||
3 | ID | ID indicator | - | Off | The ID indicator is not used (default state). |
Blue | Steady on | The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. | |||
4 | - | Service port indicator (two indicators for each port) NOTE:Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. | Meanings of service port indicators vary in different modes. For details, see Table 4-30 and Table 4-31. | ||
5 | - | Service port indicator (one indicator for each port) NOTE:Each optical port has one single-color indicator. Arrowheads show the positions of ports. | |||
6 | L/A | ETH port indicator | - | Off | The ETH port is not connected. |
Green | Steady on | The ETH port is connected. | |||
Green | Blinking | The Eth port is sending or receiving data. |
Table 4-30 Description of service port indicators in different modes (two indicators for each port)
Display Mode | Color | Status | Description |
---|---|---|---|
Default mode (LINK indicator) | Green | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |
Default mode (ACT indicator) | Yellow | Off | The port is not sending or receiving data. |
Yellow | Blinking | The port is sending or receiving data. | |
Speed mode (LINK indicator) NOTE:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | Off | The port is not connected or has been shut down. |
Green | Steady on | 1GE/10GE SFP+ port: The port is operating at 1 Gbit/s. | |
Green | Blinking | 1GE/10GE SFP+ port: The port is operating at 10 Gbit/s. |
Table 4-31 Description of service port indicators in different modes (one indicator for each port)
Display Mode | Color | Status | Description |
---|---|---|---|
Default mode | - | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |
Green | Blinking | The port is sending or receiving data. | |
Speed mode NOTE:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | Off | The port is not connected or has been shut down. |
Green | Steady on | 40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s. | |
Green | Blinking | 40GE/100GE QSFP28 port: The port is operating at 100 Gbit/s. |
The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
The switch uses pluggable fan modules for forced air cooling. Air flows in from the right and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-32 Technical specifications of the S6730-H28X6CZ-V2
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 455.0 mm (1.72 in. x 17.4 in. x 17.91 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 7.06 kg (15.56 lb) |
Weight with packaging [kg(lb)] | 10.04 kg (22.13 lb) |
Typical power consumption [W] | 203 W |
Typical heat dissipation [BTU/hour] | 692.66 BTU/hour |
Maximum power consumption [W] | 263 W |
Maximum heat dissipation [BTU/hour] | 897.38 BTU/hour |
Static power consumption [W] | 136 W |
MTBF [years] | 52.24 years |
MTTR [hours] | 2 hours |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 53.4 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 39.72 dB(A) |
Number of card slots | 1 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 4 GB |
Flash memory | Physical space: 2 GB |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | - |
Power supply surge protection [kV] |
|
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Pluggable |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from front and right and air exhaust from rear |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |