The Huawei S5731-S32ST4X is a highly reliable and high-performance switch designed for enterprise campus networks, data centers, and metropolitan area networks. Built on Huawei’s robust Versatile Routing Platform (VRP), it integrates powerful Layer 3 features, enhanced security, flexible stacking, and simplified maintenance. Its support for 1GE/2.5GE ports makes it suitable for high-speed, high-density network environments where efficiency and stability are key.
▪High Port Density:24 x 1/2.5GE SFP ports, 8 x 10/100/1000Base-T Ethernet ports, 4 x 10GE SFP+ uplink ports
▪Comprehensive Routing Protocols:Supports OSPF, BGP, RIP, IS-IS for complex Layer 3 deployments
▪iStack Technology:Allows for stacking multiple switches into one logical unit, simplifying network architecture
▪Enhanced Security Mechanisms:Includes MAC filtering, ARP detection, IP source guard, DHCP snooping, and more
▪Energy-Saving Design:Equipped with smart fan technology and power-efficient features
Product Model:S5731-S32ST4X
Fixed Ports:24 x 1/2.5GE SFP ports, 8 x 10/100/1000Base-T ports, 4 x 10GE SFP+ uplink ports
Switching Capacity:216 Gbps / 672 Gbps
Forwarding Rate:125 Mpps
MAC Address Entries:64K
VLAN Support:Up to 4094 VLANs
Power Supply:Dual pluggable AC/DC power modules, 1+1 redundancy
Cooling Mechanism:Three fans, air intake from front/sides, exhaust at rear
Dimensions (H x W x D):43.6 mm x 442.0 mm x 420.0 mm
Weight:Approx. 4.34 kg (with packaging)
▪Enterprise Access Layer:Provides high-speed and secure access in corporate campus networks
▪Data Center Access:Connects servers and other devices with high bandwidth and port flexibility
▪Metropolitan Area Networks:Delivers reliable, scalable solutions for service provider infrastructure
▪Routing Protocols:Full support for static routing, OSPF, BGP, RIP, and IS-IS
▪Multicast:Supports IGMP snooping, MLD snooping, PIM-SM/DM for efficient video/data distribution
▪IPv6 Ready:Supports full IPv6 stack, dual-stack routing and IPv6 ACLs
▪MAC Address Filtering:Prevents unauthorized devices from accessing the network
▪ARP Detection & Anti-Spoofing:Ensures authenticity of communication
▪IP Source Guard:Protects against IP spoofing attacks
▪Port Isolation:Limits unauthorized communication within a VLAN
▪Storm Control:Prevents network congestion by controlling broadcast, multicast, and unknown unicast traffic
▪iStack:Supports intelligent stacking of up to 9 switches for simplified operation and redundancy
▪Flexible Deployment:Adaptable for various enterprise and service provider topologies
▪Web GUI:Simplifies everyday configuration and monitoring
▪Command Line Interface (CLI):Full-featured CLI for advanced management
▪SNMP v1/v2/v3:Enables integration with NMS systems
▪Cloud Management:Supports Huawei iMaster NCE for intelligent operations and automation
▪Network Quality Analysis (NQA):Real-time detection of network performance
▪Remote Monitoring:Allows for centralized network oversight and issue resolution
▪Device Health Checks:Prevents failures by preemptively diagnosing issues
▪Fan Redundancy:Built-in intelligent fans offer improved cooling and reliability
▪Wide Operating Temperature:Ideal for diverse deployment conditions
▪Power Redundancy:Dual AC/DC power support for consistent uptime
▪Energy Efficient Ethernet (EEE):Reduces power consumption during low traffic periods
▪Smart Fan Control:Adjusts fan speed based on internal temperatures
▪Low Power Components:Uses efficient chipsets and materials
▪Flexible Port Compatibility:Supports various SFP transceivers (1GE/2.5GE/10GE)
▪Network Integration:Seamlessly integrates with existing Layer 2/3 networks
The switch provides up to 672 Gbps switching capacity, ensuring ample bandwidth for high-demand applications.
Yes, it includes 24 x 1/2.5GE SFP ports, ideal for high-speed wired connections in enterprise networks.
Yes, the switch supports dual pluggable AC/DC power modules, offering 1+1 redundancy for enhanced reliability.
Absolutely, the S5731-S32ST4X offers full IPv6 support, including routing, ACLs, and management protocols.
Stacking is achieved via iStack, allowing up to 9 switches to be managed as a single logical unit.
Yes, it integrates with Huawei’s iMaster NCE cloud platform for centralized and automated network operations.
The Huawei S5731-S32ST4X stands out as a top-tier enterprise switch, built to meet modern networking demands. With its extensive port options, advanced Layer 3 routing, intelligent stacking, and robust security, it is an ideal choice for businesses, data centers, and ISPs seeking a scalable, secure, and efficient switching solution. Whether it's for deployment at the access or aggregation layer, this switch delivers consistent, high-performance networking capabilities that align with future-ready digital infrastructures.
Huawei CloudEngine S5731-S32ST4X (98011813) Switch
Huawei All Series Switches New and Used
For Huawei product list and quote, please visit: https://www.hi-network.com/categories/huawei or contact us at www.hi-network.com (Email: [email protected])
Item | Details |
---|---|
Description | S5731-S32ST4X(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, without power module) |
Part Number | 98011813 |
Model | S5731-S32ST4X |
First supported version | V200R021C01 |
1 | Eight 10/100/1000BASE-T ports | 2 | Twenty-four 100/1000BASE-X ports NOTE: In V200R023C00 and later versions, 100/1000BASE-X ports can be configured to work at 2.5 Gbit/s using the port mode 2.5ge command. |
3 | Four 10GE SFP+ ports | 4 | One console port |
5 | One ETH management port | 6 | One PNP button NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 | Ground screw NOTE: It is used with a ground cable. | 8 | Power module slot 1 NOTE: Applicable power modules:
|
9 | Power module slot 2 NOTE: Applicable power modules:
| - | - |
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. | Ethernet cable |
100/1000BASE-X port | SFP | A 100/1000BASE-X port can send and receive data at 100 Mbit/s, 1000 Mbit/s, or 2.5 Gbit/s. In V200R023C00 and later versions, 100/1000BASE-X ports can be configured to work at 2.5 Gbit/s using the port mode 2.5ge command. |
|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. | Ethernet cable |
No. | Indicator | Name | Color | Status | Description |
---|---|---|---|---|---|
1 | PWR1 | Power module indicator | - | Off | No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally. |
Green | Steady on | A power module is installed in power module slot 1 and is working normally. | |||
Yellow | Steady on | The switch has two power modules installed. Any of the following situations occurs in power module slot 1:
| |||
2 | PWR2 | Power module indicator | - | Off | No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally. |
Green | Steady on | A power module is installed in power module slot 2 and is working normally. | |||
Yellow | Steady on | The switch has two power modules installed. Any of the following situations occurs in power module slot 2:
| |||
3 | SYS | System status indicator | - | Off | The system is not running. |
Green | Fast blinking | The system is starting. | |||
Green | Steady on | During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. | |||
Green | Slow blinking | The system is running normally. | |||
Red | Steady on | The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated. | |||
4 | MST | Stack indicator | - | Off | The switch is not the master switch in a stack. |
Green | Blinking | The switch is the master switch in a stack or a standalone switch. | |||
5 | ID | ID indicator | - | Off | The ID indicator is not used (default state). |
Blue | Steady on | The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. | |||
6 | - | Service port indicator (electrical port) The indicator in the upper left corner of a port indicates the indicator of a port at the top, and the indicator in the upper right corner indicates the indicator of a port at the bottom. | - | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |||
Blinking | The port is sending or receiving data. | ||||
7 | - | Service port indicator (optical port) Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. NOTE: If a power failure occurs on a device's PCB board, indicators of the last four optical ports on the device's front panel blink green cyclically at an interval of 1 second, with each indicator illuminating for 0.25 seconds. | Green | Off | The port is not connected or has been shut down. |
Steady on | A link has been established on the port. | ||||
Yellow | Off | The port is not sending or receiving data. | |||
Blinking | The port is sending or receiving data. | ||||
8 | L/A | ETH port indicator | - | Off | The ETH port is not connected. |
Green | Steady on | The ETH port is connected. | |||
Green | Blinking | The Eth port is sending or receiving data. |
The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with fans and power modules without fans cannot be installed on the same switch.
The switch has three built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 4.9 kg (10.80 lb) |
Weight with packaging [kg(lb)] | 7.43 kg (16.38 lb) |
Typical power consumption [W] | 73.56 W |
Typical heat dissipation [BTU/hour] | 250.99 BTU/hour |
Maximum power consumption [W] | 104.82 W (150 W AC or 180 W DC) 119.23 W (600 W AC) |
Maximum heat dissipation [BTU/hour] | 357.66 (150 W AC or 180 W DC) 406.82 (600 W AC) |
Static power consumption [W] | 44.5 W |
MTBF [years] | 71.54 years |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 45.47 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.79 dB(A) |
Number of card slots | 0 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Memory | 2 GB |
Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] |
|
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left,front and right, air exhaustion from behind |
PoE | Not supported |