Register now for better personalized quote!

HOT NEWS

Comprehensive Guide to the S6730-H48X6C-V2 High-Performance Switch

Jan, 23, 2025 Hi-network.com

s6730-h48x6c-v2

The S6730-H48X6C-V2 is a high-performance switch designed to meet the demands of modern data centers and enterprise networks. It offers advanced features and robust specifications to ensure reliable and efficient network operations.


Key Features

▪ High Port Density: Equipped with 48 × 10GE SFP+ ports and 6 × 40GE QSFP28 ports, providing extensive connectivity options.
▪ Flexible Uplink Options: Supports optional licenses for upgrading 40GE ports to 100GE QSFP28, allowing for scalable network growth.
▪ Advanced Cooling System: Utilizes pluggable fan modules for efficient forced air cooling, ensuring optimal performance under heavy workloads.
▪ Redundant Power Supply: Features two power module slots supporting 1+1 redundancy with pluggable AC and DC power modules, enhancing reliability.
▪ Comprehensive Management Interfaces: Includes RJ45 console and management ports, along with USB support for versatile management options.

Technical Specifications

Dimensions: 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
Weight with Packaging: 9.2 kg (20.28 lb)
Memory: 4 GB
Flash Memory: Physical space: 2 GB
Typical Power Consumption: 165 W
Number of Power Slots: 2
Number of Fan Modules: 4
Redundant Power Supply: 1+1 Pluggable AC and DC power modules
Console Port: RJ45
Management Port: RJ45
USB Support: Supported

Applications

The S6730-H48X6C-V2 is ideal for: 

▪ Data Center Aggregation: Serving as a high-density aggregation switch in data center environments.
▪ Enterprise Core Layer: Functioning as a core switch in enterprise networks, providing high-speed connectivity and advanced features.
▪ Campus Network Aggregation: Acting as an aggregation switch in campus networks, supporting various services and applications.

Conclusion

The S6730-H48X6C-V2 switch offers a comprehensive solution for organizations seeking high-performance, scalable, and reliable network infrastructure. Its advanced features and robust specifications make it a suitable choice for various networking scenarios.


Huawei CloudEngine S6730-H48X6C Switches

Huawei All Series Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected])



S6730-H48X6C-V2 Overview

Table 4-9 Basic information about the S6730-H48X6C-V2

ItemDetails
DescriptionS6730-H48X6C-V2 (48*10GE SFP+ ports, 6*40GE QSFP28 ports, optional license for upgrade to 6*100GE QSFP28, without power module)
Part Number02354HHT
ModelS6730-H48X6C-V2
First supported versionV600R022C00
RemarksBy default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands.

Components

Figure 4-4 S6730-H48X6C-V2 appearance

1

Forty-eight 10GE SFP+ ports

2

Six 40GE/100GE QSFP28 optical ports

NOTE:

By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands.

3

Ground screw

NOTE:It is used with a ground cable.

4

SSD card slot

NOTE:

This slot is reserved and cannot be used.

5

One console port

6

One ETH management port

7

One USB port

8

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

Fan module slot 1

NOTE:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

10

Fan module slot 2

NOTE:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

11

Fan module slot 3

NOTE:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

12

Fan module slot 4

NOTE:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

13

Power module slot 1

NOTE:

Applicable power modules:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module)

  • PDC1000S12-DB (1000 W DC Power Module)

14

Power module slot 2

NOTE:

Applicable power modules:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module)

  • PDC1000S12-DB (1000 W DC Power Module)

Ports

Table 4-10 Ports on the S6730-H48X6C-V2

PortConnector TypeDescriptionAvailable Components
10GE SFP+ optical portSFP+A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s.
  • GE eSFP optical modules

  • GE-CWDM eSFP optical modules

  • GE-DWDM eSFP optical modules

  • GE SFP copper module

  • 10GE SFP+ optical modules

  • 10GE-CWDM SFP+ optical modules

  • 10GE-DWDM SFP+ optical modules

  • 10GE SFP+ copper module (supported in V600R023C10 and later versions)

  • 1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables (only used for stack connection in versions earlier than V600R023C00)

  • 3 m and 10 m SFP+ AOC cables

  • 0.5 m and 1.5 m SFP+ dedicated stack cables (only used for stack connection; zero-configuration stacking supported from V600R023C00)

40GE/100GE QSFP28 optical portQSFP28

By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands.

QSFP28 optical ports cannot be split.

  • 40GE QSFP+ optical modules

  • 1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables (only used for stack connection in versions earlier than V600R023C00)

  • 10 m QSFP+ to QSFP+ AOC cable

  • 100GE QSFP28 optical modules (supported with a license loaded)

  • 1 m QSFP28 to QSFP28 high-speed copper cables (only used for stack connection in versions earlier than V600R023C00, supported with a license loaded)

  • 10 m QSFP28 to QSFP28 AOC cable (supported with a license loaded)

  • 2 m QSFP28 dedicated stack cable (only for zero-configuration stacking, supported in V600R023C00 and later versions)

Console portRJ45The console port is connected to a console for on-site configuration.

Console cable

ETH management portRJ45You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.

Ethernet cable

USB portUSB 2.0 Type A

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor.

USB flash drive

Indicators and Buttons

Figure 4-5 Indicators on the switch
Table 4-11 Description of indicators on the switch

No.

Indicator

Name

Color

Status

Description

1

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

A fault that affects services has occurred and it cannot be rectified automatically (critical alarm about hardware).

2

MST

Stack indicator

-

Off

The switch is not the master switch in a stack.

Green

Blinking

The switch is the master switch in a stack or a standalone switch.

3

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

4

-

Service port indicator (two indicators for each port)

NOTE:

Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Meanings of service port indicators vary in different modes. For details, see Table 4-12 and Table 4-13.

5

-

Service port indicator (one indicator for each port)

NOTE:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

6

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The Eth port is sending or receiving data.

7

USB

USB-based deployment indicator

-

Off

No USB flash drive is installed, or the indicator fails.

Green

Steady on

USB-based deployment succeeds. If there is no deployment configuration file, deployment will be repeatedly performed. In this case, the indicator is also steady green.

Green

Blinking

USB-based deployment is in progress.

Red

Steady on

USB-based deployment fails.

Table 4-12 Description of service port indicators in different modes (two indicators for each port)

Display Mode

Color

Status

Description

Default mode (LINK indicator)

Green

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Default mode (ACT indicator)

Yellow

Off

The port is not sending or receiving data.

Yellow

Blinking

The port is sending or receiving data.

Speed mode (LINK indicator)

NOTE:

In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command.

The default mode is automatically restored after 45s.

-

Off

The port is not connected or has been shut down.

Green

Steady on

  • 1GE/10GE SFP+ port: The port is operating at 1 Gbit/s.

  • 1GE/10GE/25GE SFP28 port: The port is operating at 1 Gbit/s or 10 Gbit/s.

Green

Blinking

  • 1GE/10GE SFP+ port: The port is operating at 10 Gbit/s.

  • 1GE/10GE/25GE SFP28 port: The port is operating at 25 Gbit/s.

Table 4-13 Description of service port indicators in different modes (one indicator for each port)

Display Mode

Color

Status

Description

Default mode

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Green

Blinking

The port is sending or receiving data.

Speed mode

NOTE:

In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command.

The default mode is automatically restored after 45s.

-

Off

The port is not connected or has been shut down.

Green

Steady on

40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s.

Green

Blinking

  • 40GE/100GE QSFP28 port: The port is operating at 100 Gbit/s.

  • 40GE QSFP+ port: The port is operating at 40 Gbit/s.

Power Supply System

The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Heat Dissipation System

The switch uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-14 Technical specifications of the S6730-H48X6C-V2

ItemSpecification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.)

Dimensions with packaging (H x W x D) [mm(in.)]175.0 mm x 650.0 mm x 550.0 mm (6.89 in. x 25.59 in. x 21.65 in.)
Chassis height [U]1 U
Chassis materialMetal
Weight without packaging [kg(lb)]5.84 kg (12.87 lb)
Weight with packaging [kg(lb)]9.2 kg (20.28 lb)
Typical power consumption [W]165 W
Typical heat dissipation [BTU/hour]563 BTU/hour
Maximum power consumption [W]

High temperature 45°C (113°F), 100% traffic, and dual power modules: 207 W

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 291 W

Maximum heat dissipation [BTU/hour]

High temperature 45°C (113°F), 100% traffic, and dual power modules: 706.30

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 992.92

Static power consumption [W]97 W
MTBF [years]56.87 years
MTTR [hours]2 hours
Availability> 0.99999
Noise at normal temperature (acoustic power) [dB(A)]65 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)]52 dB(A)
Number of card slots0
Number of power slots2
Number of fans modules4
Redundant power supply

1+1

Pluggable AC and DC power modules can be used together in the same switch.

Long-term operating temperature [°C(°F)]-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Devices cannot start when the temperature is lower than 0°C (32°F).

When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).

Storage temperature [°C(°F)]-40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH]5% to 95%, noncondensing
Long-term operating altitude [m(ft.)]0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)]0-5000 m (0-16404 ft.)
Power supply modePluggable power supply
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC; 50/60 Hz

  • High-voltage DC input: 240 V DC

  • DC input: –48 V DC to –60 V DC

Input voltage range [V]
  • AC input: 90–290 V AC; 45–65 Hz

  • High-voltage DC input: 190 V DC to 290 V DC

  • DC input: -38.4 V DC to -72 V DC

Maximum input current [A]The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.
Memory4 GB
Flash memoryPhysical space: 2 GB
Console portRJ45
Eth Management portRJ45
USBSupported
RTCSupported
RPS inputNot supported
Service port surge protection [kV]-
Power supply surge protection [kV]
  • AC power module configured: ±6 kV in differential mode, ±6 kV in common mode

  • DC power module configured: ±2 kV in differential mode, ±4 kV in common mode

Ingress protection level (dustproof/waterproof)IP20
Types of fansPluggable
Heat dissipation modeHeat dissipation with fan, intelligent fan speed adjustment
Airflow directionAir intake from front, air exhaustion from rear (front-to-rear)
PoENot supported
Certification

EMC certification

Safety certification

Manufacturing certification


tag-icon Hot Tags : Huawei Switches

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.