Register now for better personalized quote!

HOT NEWS

Huawei CloudEngine S6730-H24X4Y4C: A High-Performance Enterprise Switch for Modern Networks

Jan, 24, 2025 Hi-network.com

s6730-h24x4y4c

The Huawei CloudEngine S6730-H24X4Y4C is a next-generation enterprise-class switch designed to meet the demands of modern high-speed networks. It offers advanced features and robust performance, making it suitable for both core and aggregation layers in enterprise networks.


Key Features

The S6730-H24X4Y4C switch boasts several notable features:

▪ High Port Density: 24 x 10GE SFP+ ports, 4 x 25GE SFP28 ports, and 4 x 100GE QSFP28 ports.
▪ Advanced Security: Supports MACsec encryption for secure data transmission.
▪ VXLAN Support: Enables network virtualization for flexible and scalable network architectures.
▪ High Reliability: Features redundant power supplies and fans for enhanced system reliability.
▪ Comprehensive IPv6 Support: Fully compatible with IPv6, ensuring future-proof networking.

Technical Specifications

The S6730-H24X4Y4C switch comes with the following technical specifications: 

Ports: 24 x 10GE SFP+ ports, 4 x 25GE SFP28 ports, 4 x 100GE QSFP28 ports. 

Switching Capacity: 1.48 Tbps.Forwarding Performance: 1,100 Mpps. 

MAC Address Table: Supports up to 288K MAC addresses. 

Jumbo Frame Support: Up to 9,216 bytes.Power Supply: Dual pluggable power modules, supporting 1+1 redundancy. 

Dimensions (H x W x D): 43.6 mm x 442.0 mm x 220.0 mm.Weight: Approximately 4.65 kg.


Advanced Security Features

Security is a paramount concern in modern networks. The S6730-H24X4Y4C addresses this with:MACsec Encryption: Ensures secure data transmission by providing point-to-point security on Ethernet links.Access Control Lists (ACLs): Offer granular traffic filtering to protect against unauthorized access and attacks.Storm Control: Prevents network disruptions caused by broadcast, multicast, or unknown unicast traffic storms.


High Availability and Reliability

To ensure continuous network operation, the S6730-H24X4Y4C is equipped with:Redundant Power Supplies: Dual hot-swappable power modules provide 1+1 redundancy, ensuring uninterrupted power.Hot-Swappable Fan Modules: Three built-in fans support forced air cooling, with airflow from the left side and front panel to the right side.Ethernet Ring Protection Switching (ERPS): Provides rapid network recovery in ring topologies, minimizing downtime.


Comprehensive IPv6 Support

As networks transition to IPv6, the S6730-H24X4Y4C ensures seamless integration with:Dual-Stack Architecture: Supports both IPv4 and IPv6 protocols, facilitating smooth migration.IPv6 Routing Protocols: Includes support for OSPFv3, BGP4+, and IS-ISv6 for dynamic routing in IPv6 networks.IPv6 ACLs: Provide traffic filtering capabilities for IPv6 traffic, enhancing security.


Energy Efficiency

The S6730-H24X4Y4C is designed with energy efficiency in mind:Energy-Efficient Ethernet (EEE): Reduces power consumption during periods of low network activity.Intelligent Fan Speed Adjustment: Automatically adjusts fan speed based on temperature, reducing energy usage and noise.


Management and Maintenance

Efficient network management is facilitated through:Command-Line Interface (CLI): Provides a familiar interface for network administrators to configure and monitor the switch.Simple Network Management Protocol (SNMP): Allows for centralized management and monitoring of network devices.Remote Monitoring (RMON): Offers proactive network monitoring and troubleshooting capabilities.


Application Scenarios

The versatility of the S6730-H24X4Y4C makes it suitable for various deployment scenarios:Enterprise Campus Networks: Serves as a core or aggregation switch, providing high-speed connectivity and advanced features.Data Center Top-of-Rack (ToR): Offers high-density 10GE and 25GE ports for server connectivity, with 100GE uplinks to the aggregation layer.Metropolitan Area Networks (MANs): Functions as an aggregation switch, supporting high-bandwidth services and advanced QoS features.


Conclusion

The Huawei CloudEngine S6730-H24X4Y4C is a powerful and versatile switch designed to meet the demands of modern enterprise networks.


Huawei CloudEngine S6730-H24X4Y4C Switches

Huawei All Series Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected])



S6730-H24X4Y4C (02353NRD) Overview

Table 4-200 Basic information about the S6730-H24X4Y4C

ItemDetails
DescriptionS6730-H24X4Y4C (24*10GE SFP+ ports, 4*25GE SFP28 ports, 4*100GE QSFP28 ports, without power module)
Part Number02353NRD
ModelS6730-H24X4Y4C
First supported versionV200R020C00

Components

Figure 4-85 S6730-H24X4Y4C appearance

1

Power module slot 1

NOTE:

Applicable power modules:

  • PDC260S12-DL (260 W DC Power Module)

  • PAC300S12-CL (300 W AC&240 V DC Power Module)

2

Power module slot 2

NOTE:

Applicable power modules:

  • PDC260S12-DL (260 W DC Power Module)

  • PAC300S12-CL (300 W AC&240 V DC Power Module)

3

Twenty-four 10GE SFP+ ports

NOTE:

In V200R021C00 and later versions, a RTU license can be loaded to increase the port rate to 25 Gbit/s.

4

Four 1GE/10GE/25GE SFP28 optical ports

5

Four 40GE/100GE QSFP28 optical ports

6

One console port

7

One ETH management port

8

One USB port

9

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

-

Ground screw

NOTE:

The ground screw is on the left side of the chassis.

Ports

Table 4-201 Ports on the S6730-H24X4Y4C

PortConnector TypeDescriptionAvailable Components
10GE SFP+ optical portSFP+

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s.

In V200R021C00 and later versions, a RTU license can be loaded to increase the port rate to 25 Gbit/s.

  • GE eSFP optical modules

  • GE-CWDM eSFP optical modules

  • GE-DWDM eSFP optical modules

  • GE SFP copper module

  • 10GE SFP+ optical modules (OSXD22N00 and SFP-10G-ZR not supported)

  • 10GE SFP+ copper module (supported in V200R023C10 and later versions)

  • 1 m, 2 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables

  • 3 m and 10 m SFP+ AOC cables

  • 0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)

  • 25GE SFP28 optical modules (need a license loaded)

  • 1 m SFP28 high-speed copper cable (need a license loaded)

  • 3 m, 5 m, 7 m, and 10 m SFP28 AOC cables (need a license loaded)

1GE/10GE/25GE SFP28 optical portSFP28

A 1GE/10GE/25GE SFP28 optical port sends and receives service data at 1 Gbit/s, 10 Gbit/s, or 25 Gbit/s.

When a 25GE optical module is connected to a port, the port can automatically adjust its rate to 25 Gbit/s.

When a 10GE optical module is connected to a port, the port can automatically adjust its rate to 10 Gbit/s.

Before installing a GE optical module or GE copper module on a port, run the port mode ge command to configure the port to work at 1 Gbit/s.

  • GE eSFP optical modules

  • GE-CWDM eSFP optical modules

  • GE-DWDM eSFP optical modules

  • GE SFP copper module

  • 10GE SFP+ optical modules (OSXD22N00 and SFP-10G-ZR not supported)

  • 10GE SFP+ copper module (supported in V200R023C10 and later versions)

  • 25GE SFP28 optical modules

  • 1 m, 2 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables

  • 3 m and 10 m SFP+ AOC cables

  • 1 m SFP28 high-speed copper cable

  • 3 m, 5 m, 7 m, and 10 m SFP28 AOC cables

40GE/100GE QSFP28 optical portQSFP28

A 40GE/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit/s or 100 Gbit/s.

A QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.

  • 40GE QSFP+ optical modules

  • 100GE QSFP28 optical modules

  • 1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables

  • 10 m QSFP+ to QSFP+ AOC cable

  • 1 m QSFP28 to QSFP28 high-speed copper cable

  • 10 m QSFP28 to QSFP28 AOC cable

  • 2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)

Console portRJ45The console port is connected to a console for on-site configuration.

Console cable

ETH management portRJ45

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.

You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.

Ethernet cable

USB portUSB 2.0 Type A

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

USB flash drive

Indicators and Buttons

Figure 4-86 Indicators on the switch
Table 4-202 Description of indicators on the switch

No.

Indicator

Name

Color

Status

Description

1

PWR1

Power module indicator

-

Off

No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 1 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 1:

  • A power module is available in this slot but it is not connected to a power source.

  • The power module in this slot has failed.

2

PWR2

Power module indicator

-

Off

No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 2 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 2:

  • A power module is available in this slot but it is not connected to a power source.

  • The power module in this slot has failed.

3

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

4

MST

Stack indicator

-

Off

  • If you are not changing the indicator mode (default): The switch is a standby or slave switch in a stack or the stacking function is not enabled on the switch.

  • If you are changing the indicator mode: The stack mode is not selected.

Green

Steady on

The stack mode is selected. The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch.

Green

Blinking

  • If you are not changing the indicator mode (default): The switch is the master switch in a stack or a standalone switch with the stacking function enabled.

  • If you are changing the indicator mode: The stack mode is selected. The switch is the master switch in a stack or a standalone switch, and the service port indicators show the stack ID of the master switch. After 45 seconds, the service port indicators automatically restore to the status mode.

5

SPEED

Speed indicator

-

Off

The speed mode is not selected.

Green

Steady on

The speed mode is selected, and service port indicators show the speed of each port.

6

MODE

Mode switch button

-

-

  • When you press this button once, the service port indicators change to the stack mode and show the stack ID of the local switch.

  • When you press this button a second time, the service port indicators change to the speed mode and show the speed of each service port.

  • When you press this button a third time, the service port indicators restore to the default mode and show the connection status and link activity of each service port.

If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the SPEED indicator is off.

NOTE:Hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:
  • If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:

    • If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.

    • If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore the default status.

  • If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.

7

-

Optical service port indicator (two indicators for each port)

Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Meanings of service port indicators vary in different modes. For details, see Table 4-203 and Table 4-204.

8

-

Optical service port indicator (one indicator for each port)

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

9

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

10

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The ETH port is sending or receiving data.

11

USB

USB-based deployment indicator

-

Off

  • No USB flash drive is connected to the switch.

  • The USB port is damaged.

  • The indicator is damaged.

  • The USB flash drive does not have any configuration file and cannot be used for deployment.

  • The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Green

Blinking

The system is reading data from a USB flash drive.

Yellow

Steady on

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.

Table 4-203 Description of service port indicators in different modes (two indicators for each port)

Display Mode

Color

Status

Description

Default mode (LINK indicator)

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Default mode (ACT indicator)

-

Off

The port is not connected or has been shut down, or no data is transmitted or received.

Yellow

Blinking

The port is sending or receiving data.

MST stack mode (LINK and ACT indicators)

-

Off

Port indicators do not show the stack ID of the switch.

Green and yellow

Steady on simultaneously

The switch is not the master switch in a stack.
  • If the indicator of a port is steady on, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are steady on, the stack ID of the switch is 0.

Green and yellow

Blinking simultaneously

The switch is the master switch in a stack.
  • If the indicator of a port is blinking, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are blinking, the stack ID of the switch is 0.

Speed mode (LINK indicator)

-

Off

The port is not connected or has been shut down.

Green

Steady on

  • GE/10GE SFP+ port: The port is operating at 1 Gbit/s.

  • 1GE/10GE/25GE SFP28 port: The port is operating at 1 Gbit/s or 10 Gbit/s.

Green

Blinking

  • GE/10GE SFP+ port: The port is operating at 10 Gbit/s.

  • 1GE/10GE/25GE SFP28 port: The port is operating at 25 Gbit/s.

Table 4-204 Description of service port indicators in different modes (one indicator for each port)

Display Mode

Color

Status

Description

Default mode

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Green

Blinking

The port is sending or receiving data.

Speed mode

-

Off

The port is not connected or has been shut down.

Green

Steady on

  • 1GE/10GE/25GE SFP28 port: The port is operating at 1 Gbit/s or 10 Gbit/s.

  • 40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s.

Green

Blinking

  • 1GE/10GE/25GE SFP28 port: The port is operating at 25 Gbit/s.

  • 40GE/100GE QSFP28 port: The port is operating at 100 Gbit/s.

Power Supply System

The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Heat Dissipation System

The switch has three built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-205 Technical specifications of the S6730-H24X4Y4C

ItemSpecification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.40 in. x 9.09 in.)

Dimensions with packaging (H x W x D) [mm(in.)]115.0 mm x 545.0 mm x 360.0 mm (4.53 in. x 21.46 in. x 14.17 in.)
Chassis height [U]1 U
Chassis materialMetal
Weight without packaging [kg(lb)]3.4 kg (7.5 lb)
Weight with packaging [kg(lb)]4.65 kg (10.25 lb)
Typical power consumption [W]186 W
Typical heat dissipation [BTU/hour]634.65 BTU/hour
Maximum power consumption [W]253 W
Maximum heat dissipation [BTU/hour]863.26 BTU/hour
Static power consumption [W]116 W
MTBF [years]54.68 years
MTTR [hours]2 hours
Availability> 0.99999
Noise at normal temperature (acoustic power) [dB(A)]64.5 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)]51.7 dB(A)
Number of card slots0
Number of power slots2
Number of fans modules3
Redundant power supply

1+1

Pluggable AC and DC power modules can be used together in the same switch.

Long-term operating temperature [°C(°F)]-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The device cannot start when the temperature is lower than 0°C (32°F).

When the QSFP-100G-ER4 or QSFP-100G-LR1 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).

Storage temperature [°C(°F)]-40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH]5% to 95%, noncondensing
Long-term operating altitude [m(ft.)]0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)]0-5000 m (0-16404 ft.)
Power supply modePluggable power supply
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC; 50/60 Hz

  • High-voltage DC input: 240 V DC

  • DC input: –48 V DC to –60 V DC

Input voltage range [V]
  • AC input: 90–290 V AC; 45–65 Hz

  • High-voltage DC input: 190 V DC to 290 V DC

  • DC input: -38.4 V DC to -72 V DC

Maximum input current [A]The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.
Memory4 GB
Flash memory2 GB in total. To view the available flash memory size, run the display version command.
Console portRJ45
Eth Management portRJ45
USBSupported
RTCSupported
RPS inputNot supported
Service port surge protection [kV]-
Power supply surge protection [kV]
  • AC power module configured: ±6 kV in differential mode, ±6 kV in common mode

  • DC power module configured: ±2 kV in differential mode, ±4 kV in common mode

Ingress protection level (dustproof/waterproof)IP20
Types of fansBuilt-in
Heat dissipation modeHeat dissipation with fan, intelligent fan speed adjustment
Airflow directionAir intake from left and front, air exhaustion from right
PoENot supported
Certification

EMC certification

Safety certification

Manufacturing certification


tag-icon Hot Tags : Huawei Switches

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.