The Huawei S6730-H48X6CZ-V2 is a next-generation enterprise-class core and aggregation switch, designed to meet the demands of modern high-performance networks. Part of Huawei's CloudEngine S6730-H-V2 series, this switch offers advanced features and capabilities suitable for large-scale enterprise campuses, data centers, and metropolitan area networks (MANs).
The S6730-H48X6CZ-V2 boasts a range of features that enhance network performance, reliability, and scalability:
▪ High Port Density: Equipped with 48 × 10 Gigabit SFP+ ports and 6 × 40/100 Gigabit QSFP28 ports, providing substantial bandwidth for data-intensive applications.
▪ Expansion Slot: Includes one expansion slot, allowing for future upgrades and customization to meet evolving network requirements.
▪ High Switching Capacity: Offers a switching capacity of up to 2.4 Tbps, ensuring efficient data processing and minimal latency.
▪ Advanced Virtualization: Supports Virtual Extensible LAN (VXLAN) technology, enabling network virtualization and the creation of multiple virtual networks on a single physical infrastructure.
▪ Intelligent Operations and Maintenance (O&M): Utilizes telemetry and works with Huawei's CampusInsight to provide real-time network monitoring and rapid fault detection, ensuring optimal user experience.
▪ Energy Efficiency: Designed with energy-saving features to reduce power consumption without compromising performance.
The S6730-H48X6CZ-V2 is engineered to deliver robust performance and flexibility:
Ports: 48 × 10 Gigabit SFP+ ports 6 × 40/100 Gigabit QSFP28 ports
Expansion Slot: 1 expansion slot for additional modules Switching Capacity: Up to 2.4 Tbps
Forwarding Rate: Up to 1920 Mpps
Power Supply: Supports dual pluggable power modules with 1+1 redundancy Dimensions (W × D × H): 442 mm × 420 mm × 43.6 mm Weight: Approximately 7.5 kg Operating Temperature: 0°C to 45°C Operating Humidity: 5% to 95% (non-condensing)
The versatility of the S6730-H48X6CZ-V2 makes it suitable for various networking environments: Large-Scale Enterprise Campus: Serves as a core or aggregation switch, providing high-speed connectivity and advanced features to support the demands of large enterprise networks. Data Centers: Offers high-density 10 GE ports and advanced virtualization features, making it ideal for data center applications requiring efficient and scalable networking solutions. Metropolitan Area Networks (MANs): Can be deployed at the access layer of MANs to build high-performance, multi-service, and highly reliable networks for Internet Service Providers (ISPs).
The S6730-H48X6CZ-V2 incorporates several advanced features to enhance network functionality: Free Mobility: Ensures a consistent user experience regardless of user location or IP address, fully meeting enterprises' demands for mobile offices. Intelligent Stack (iStack): Supports the iStack function, allowing multiple switches to be combined into a single logical switch for simplified management and enhanced scalability. Comprehensive Security: Offers a range of security features, including Access Control Lists (ACLs), 802.1X authentication, and DHCP snooping, to protect the network from various threats. Quality of Service (QoS): Provides advanced QoS capabilities to prioritize critical traffic and ensure optimal performance for mission-critical applications.
Efficient management and maintenance are crucial for network reliability: Cloud Management: Supports cloud-based network management, allowing for centralized control and monitoring of network devices, simplifying operations, and reducing maintenance costs. Telemetry: Collects device data in real-time, enabling proactive monitoring and rapid troubleshooting to maintain optimal network performance.
1. What is the primary use case for the Huawei S6730-H48X6CZ-V2 switch?
The Huawei S6730-H48X6CZ-V2 switch is designed for enterprise campus networks, data centers, and metropolitan area networks (MANs). It provides high-speed data transmission, advanced virtualization features, and reliable network performance.
2. How many ports does the S6730-H48X6CZ-V2 have?
This switch features 48 × 10 Gigabit SFP+ ports and 6 × 40/100 Gigabit QSFP28 ports, offering high-density connectivity options.
3. Does this switch support network virtualization?
Yes, it supports VXLAN (Virtual Extensible LAN) technology, allowing for network segmentation and efficient resource utilization in large-scale deployments.
4. What redundancy features are available in this switch?
The S6730-H48X6CZ-V2 supports dual pluggable power modules with 1+1 redundancy, ensuring continuous operation in case of power failure.
5. Can this switch be managed remotely?
Yes, it supports cloud-based network management and telemetry for real-time monitoring and proactive maintenance.
6. Is this switch energy-efficient?
Yes, it is designed with energy-saving features to reduce power consumption while maintaining high-performance networking capabilities.
The Huawei S6730-H48X6CZ-V2 is a powerful and versatile switch designed to meet the high-performance networking needs of enterprises, data centers, and service providers. With its high port density, robust security, advanced virtualization, and intelligent O&M capabilities, it is an excellent choice for organizations looking to enhance network efficiency and scalability. Its VXLAN support, iStack technology, cloud-based management, and QoS optimization make it a future-proof investment for businesses requiring high-speed, reliable, and secure network infrastructure. Whether deployed as a core, aggregation, or access switch, the S6730-H48X6CZ-V2 delivers outstanding performance, security, and operational efficiency.
Huawei CloudEngine S6730-H48X6C Switch
Huawei All Series Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected])
Table 4-57 Basic information about the S6730-H48X6CZ-V2
Item | Details |
---|---|
Description | S6730-H48X6CZ-V2 (48*10GE SFP+ ports, 6*40GE QSFP ports, optional license for upgrade to 6*100GE QSFP28 ports, 1*expansion slot, without power module) |
Part Number | 02354VUD |
Model | S6730-H48X6CZ-V2 |
First supported version | V600R022C00 |
Remarks | By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. |
Figure 4-20 S6730-H48X6CZ-V2 appearance
1 | Forty-eight 10GE SFP+ optical ports | 2 | Six 40GE/100GE QSFP28 optical ports NOTE:By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. |
3 | One PNP button NOTICE:To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 4 | Ground screw NOTE:It is used with a ground cable. |
5 | Card slot NOTE:In versions earlier than V600R024C00, this card slot is reserved. Applicable card: HSIC-X08S000 (available since V600R024C00 version) | 6 | One USB port |
7 | One ETH management port | 8 | One console port |
9 | Fan module slot 1 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Fan module slot 2 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | Fan module slot 3 NOTE:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | Power module slot 1 NOTE:Applicable power modules:
|
13 | Power module slot 2 NOTE:Applicable power modules:
| - | - |
Table 4-58 Ports on the S6730-H48X6CZ-V2
Port | Connector Type | Description | Available Components |
---|---|---|---|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE/100GE QSFP28 optical port | QSFP28 | By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. In V600R023C10 and later versions, the last two 100GE ports can each be split into four 25GE ports using a command. The port can be automatically converted into four 10GE ports using one-to-four QSFP+ optical modules or AOC optical cables. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
The S6730-H48X6CZ-V2 has the same types of indicators as the S6730-H28X6CZ-V2. For details, see the S6730-H28X6CZ-V2.
The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
The switch uses pluggable fan modules for forced air cooling. Air flows in from the right and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-59 Technical specifications of the S6730-H48X6CZ-V2
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 455.0 mm (1.72 in. x 17.4 in. x 17.91 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 7.48 kg (16.49 lb) |
Weight with packaging [kg(lb)] | 10.46 kg (23.06 lb) |
Typical power consumption [W] | 234 W |
Typical heat dissipation [BTU/hour] | 798.43 BTU/hour |
Maximum power consumption [W] | 327 W |
Maximum heat dissipation [BTU/hour] | 1115.76 BTU/hour |
Static power consumption [W] | 157 W |
MTBF [years] | 48.99 years |
MTTR [hours] | 2 hours |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 53.4 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 39.72 dB(A) |
Number of card slots | 1 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 4 GB |
Flash memory | Physical space: 2 GB |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | - |
Power supply surge protection [kV] |
|
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Pluggable |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from front and right and air exhaust from rear |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |