Register now for better personalized quote!
S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004) S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004) S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)
  • S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)
  • S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)
  • S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)

Huawei Switch S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)

1675
4.5
4.5/5.0
Q/A
1 sold/Mon
Detail: S5732-H24S6Q (20*GE SFP ports, 4*10GE SFP+ ports, 6*40GE QSFP ports, without power module)
Model: S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)
Condition: Factory Sealed New
Related: OEM eSFP-GE-ZX100-SM1550 (02315206) Huawei Compatible 1000BASE-EZX SFP 1550nm 100km Transceiver Module OEM SFP-GE-BXU1-SC (02310TQH) Huawei Compatible 1000Base TX1490nm/RX1310nm 10km SC Connector SFP Optical Transceiver Module Huawei Switch S5732-H48S6Q (02353AJU/02353AJU-001/02353AJU-003/02353AJU-004)
Warranty:
3 Years-Warranty
100% Money-back
Free After-Sales Service
Shipping:
Air Shipping to United States
, Most Customers Receive during 5-7 Days
?
If you finish the payment today,
your order will arrive within the
estimated delivery time.
Ships to:
17
2-7 Days US$
Payment:
  • Pay by wire transfer.
  • Pay with your paypal.
  • Pay with your Visa credit card.
  • Pay with your Mastercard credit card.
  • Pay with your Discover Card.
  • Pay by Western Union.
More
Quantity
- +
add to Cart quick quote
add to Cart quick quote
  • Description
  • Specification
  • Reviews
  • Q&A
  • Warranty
  • Download

Huawei Switch S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)


The Huawei CloudEngine S5732-H series switches are the next-generation enhanced all-optical Ethernet switches developed by Huawei. The CloudEngine S5732-H builds on Huawei's unified Versatile Routing Platform (VRP) and boasts various IDN features.



Quick Specification


Table 1 shows the quick specification.

Model

S5732-H24S6Q

Part Number

02353AJS

02353AJS-001

02353AJS-003

02353AJS-004

Fixed port

20 x GE SFP ports, 4 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports

Dimensions (W x D x H)

442 mm x 420 mm x 43.6 mm

Chassis height

1 U

Power supply type

• 600 W AC (pluggable)
• 1000 W DC (pluggable)

Maximum voltage range

• AC input (600 W AC): 90 V AC to 290 V AC, 45 Hz to 65 Hz
• High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification)
• DC input (1000 W DC): -36 V DC to -72V DC

Maximum power consumption

229 W

Noise

• Under normal temperature (sound power): 65dB (A)
• Under high temperature (sound power): 88dB (A)
• Under normal temperature (sound pressure): 52dB (A)


Figure 1 shows the appearance ofS5732-H24S6Q.

front-s5732-h24s6q-datasheet



Product Details


The S5732-H series switches provides these features and highlights:

* Enabling Networks to Be More Agile for Services

* Delivering Abundant Services More Agilely

* Providing Fine Granular Network Management More Agilely

* Comprehensive VPN Technologies

* Flexible Ethernet Networking

* Various Security Control Methods

* Mature IPv6 Features

* Intelligent Stack (iStack)

* VXLAN Features

* Big Data Security Collaboration

* Intelligent O&M

* Intelligent Upgrade

* Open Programmability System (OPS)


Figure 2 and 3 show the indicators on the S5732-H24S6Q.

indicators1-s5732-h24s6q-datasheet

indicators2-s5732-h24s6q-datasheet


Table 2 show the description of indicators on the S5732-H24S6Q.

No.

Indicator

Name

Color

Status

Description

(1)

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

(2)

MST

Stack indicator

-

Off

The switch is not the master switch in a stack.

Green

Blinking

The switch is the master switch in a stack or a standalone switch.

(3)

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

(4)

-

Service port indicator (GE/10GE optical port)

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

-

Off

The port is not sending or receiving data.

Yellow

Blinking

The port is sending or receiving data.

(5)

-

Service port indicator (40GE/100GE optical port)

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Blinking

The port is sending or receiving data.

(6)

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Blinking

The Eth port is sending or receiving data.

(7)

USB

USB-based deployment indicator

-

Off

No USB flash drive is connected to the switch.
The USB port is damaged.
The indicator is damaged.
The USB flash drive does not have any configuration file and cannot be used for deployment.
The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Blinking

The system is reading data from a USB flash drive.

Yellow

Steady on

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.


The Modules


Table 3 shows the recommended products.

Model

Description

PAC600S12-CB

600W AC Power Module (Back to Front, Power panel side exhaust)

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module (850nm, 0.55km, LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 40km, LC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 40km, LC)

S-SFP-GE-LH80-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 80km, LC)

SFP-GE-ZBXU1

Optical Transceiver, eSFP, GE, BiDi Single-mode Module (1490nm (Tx)/1570nm (Rx), 80km, LC)

SFP-GE-LX-SM1490-BIDI

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 10km, LC)

eSFP-GE-ZX100-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 100km, LC)

SFP-GE-ZBXD1

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (1570nm (Tx)/1490nm (Rx), 80km, LC)

LE2MGSC40DE0

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 40km, LC)

LE2MGSC40ED0

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 40km, LC)

SFP-GE-LX-SM1310-BIDI

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 10km, LC)

SFP-GE-BXU1-SC

1000Base, BIDI Optical Transceiver, SFP, GE, Single-mode Module (TX1490nm/RX1310nm, 10km, SC)


Compare to Similar Items


Table 4 shows the comparison.

Model

S5732-H24S6Q

S5732-H48S6Q

Fixed port

20 x GE SFP ports, 4 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports

44 x GE SFP ports, 4 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports

Dimensions (W x D x H)

442 mm x 420 mm x 43.6 mm

442 mm x 420 mm x 43.6 mm

Chassis height

1 U

1 U

Chassis weight (including packaging)

8.9 kg

9.2 kg

Power supply type

• 600 W AC (pluggable)
• 1000 W DC (pluggable)

• 600 W AC (pluggable)
• 1000 W DC (pluggable)

Maximum power consumption

229 W

255 W

Surge protection specification (power port)

• AC power port: ±6 kV in differential mode, ±6 kV in common mode
• DC power port: ±2 kV in differential mode, ±4 kV in common mode

• AC power port: ±6 kV in differential mode, ±6 kV in common mode
• DC power port: ±2 kV in differential mode, ±4 kV in common mode


Get More Information


Do you have any question about the S5732-H24S6Q (02353AJS/02353AJS-001/02353AJS-003/02353AJS-004)?

Contact us now via [email protected].

Specific Data Sheet:


S5732-H24S6Q Specification

Technical specifications

Fixed port

20 x GE SFP ports, 4 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports

Dimensions (W x D x H)

442 mm x 420 mm x 43.6 mm

Chassis height

1 U

Chassis weight (including packaging)

8.9 kg

Power supply type

• 600 W AC (pluggable)
• 1000 W DC (pluggable)

Maximum voltage range

• AC input (600 W AC): 90 V AC to 290 V AC, 45 Hz to 65 Hz
• High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification)
• DC input (1000 W DC): -36 V DC to -72V DC

Maximum power consumption

229 W

Noise 

• Under normal temperature (sound power): 65dB (A)
• Under high temperature (sound power): 88dB (A)
• Under normal temperature (sound pressure): 52dB (A)

Operating temperature

• 0-1800 m altitude: -5°C to +45°C
• 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m.

Storage temperature

-40℃ to +70℃

Relative humidity

5% to 95% (non-condensing)

Surge protection specification (power port)

• AC power port: ±6 kV in differential mode, ±6 kV in common mode
• DC power port: ±2 kV in differential mode, ±4 kV in common mode

Heat dissipation

Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans

Service Features

MAC address table

IEEE 802.1d standards compliance
128K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses

VLAN

4094 VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
VLAN mapping

Wireless service

AP access control, AP domain management, and AP configuration template management
Radio management, unified static configuration, and dynamic centralized management
WLAN basic services, QoS, security, and user management
CAPWAP, tag/terminal location, and spectrum analysis

Ethernet loop protection

RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching
SEP
ERPS (G.8032)
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
BPDU protection, root protection, and loop protection

MPLS

MPLS L3VPN
MPLS L2VPN (VPWS/VPLS)
MPLS-TE
MPLS QoS

IP routing

Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy
Up to 192K FIBv4 entries
Up to 80K FIBv6 entries

Interoperability

VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar to DTP
VLAN Central Management Protocol (VCMP), similar to VTP

IPv6 features

Up to 80K ND entries
PMTU
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types
Multicast Listener Discovery snooping (MLDv1/v2)
IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN

Multicast

IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics
IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM
MSDP
MVPN

QoS/ACL

Rate limiting in the inbound and outbound directions of a port
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues per port
DRR, SP and DRR+SP queue scheduling algorithms
WRED
Re-marking of the 802.1p and DSCP fields of packets
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address,
destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol
type, and VLAN ID
Queue-based rate limiting and shaping on ports

Security

Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, port number, and VLAN ID
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and limit on the number of users on a port
AAA authentication, RADIUS authentication, and HWTACACS authentication
NAC
SSH V2.0
HTTPS
CPU protection
Blacklist and whitelist
Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets
Secure Boot
IPSec
ECA
Deception

Reliability

LACP
E-trunk
Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag)
ITU-Y.1731
DLDP
LLDP
BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route

VXLAN*

VXLAN L2 and L3 gateways
Centralized and distributed gateway
BGP-EVPN
Configured through the NETCONF protocol

Super Virtual Fabric (SVF)

Working as an SVF Parent to vertically virtualize downlink switches and APs as one device for
management.
A two-layer client architecture is supported.
IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on
a port can be configured.
ASs can be independently configured. Services that are not supported by templates can be configured on
the parent.
Third-party devices are allowed between SVF parent and clients.

iPCA

Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio
Collection of statistics on the number of lost packets and packet loss ratio at network and device levels

TWAMP

Two-way IP link performance measurement
Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter

Management and maintenance

iStack, with up to 9 member switches in a stack
SNMP v1/v2c/v3
RMON
Smart Application Control (SAC)
Web-based NMS
System logs and alarms of different levels
GVRP
MUX VLAN
NetStream
Intelligent O&M

*CloudEngine S5732-H series switches require the VXLAN license or N1 advanced software package to support the VXLAN feature.


Customer Reviews

5
4.7
(36 reviews)
5 Stars
4
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0
Posted on 06/07/2024
Verified Buyer
4.8
Happy with this purchase.

Do you have other questions or feedback? You may write here:

*Question:
*Use your name:
*Email:

What is Guaranteed.

After receiving your order, take a full month to try it out. If you find quality is not good , we'll take it back and refund your money. Your complete satisfaction is GUARANTEED or your money back. That's guaranteed.


After your order items which are available. We will use most fast delivery way to global countries. Normally we will ship out cargos during 3 -5 days. And international delivery will take about 3- 10 days according to your location.


Service Never Ends.

Hardwares Warrany Time:

Original New Sealed Hardware: 3 Years
Refurbished/Used Original Devices: 1 Year

After warranty time, you also can contact us to return back for repair service. Everything you purchase from HI-NETWORK.COM. We will offer lifetime online service support for your any possible questions. 


Resources Downloads

Support and Resources

Related Products

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.