Detail: | S5701-28X-LI-24S-AC (20 Gig SFP, 4 dual-purpose 10/100/1000 and SFP, 4 10 Gig SFP+, AC 110/220V) |
Model: | S5701-28X-LI-24S-AC (02357676) |
Condition: | Factory Sealed New |
Related: | OEM S-SFP-FE-LH40-SM1310 (02317344) Huawei Compatible 100BASE-EX SFP 1310nm 40km DOM Duplex LC SMF Transceiver Module Genuine New OSX010000 (02318170) Huawei 10GBASE-LR SFP+ 1310nm 10km DOM Duplex LC SMF Optical Transceiver Module Huawei Switch S5701-28X-LI-AC (02357675) Huawei Switch S5700-28X-LI-24S-AC (02355271) |
Warranty: |
3 Years-Warranty
100% Money-back
Free After-Sales Service
|
Shipping: |
Air Shipping to
United States
, Most Customers Receive during 5-7 Days
?
If you finish the payment today,
your order will arrive within the estimated delivery time. |
Ships to:
5.5
|
2-7 Days
US$
|
Payment: |
More
|
The S5701-28X-LI-24S-AC gigabit enterprise switch is next-generation energy-saving switch developed by Huawei. With front power sockets, it can be installed in the 300 mm deep cabinet and be maintained through the front panel, saving space in small equipment rooms, widely used in various application scenarios like enterprise park access, convergence, gigabit access of data center application scenarios. Using advanced energy conservation technology plus twenty-four GE SFP ports, four Combo 10/100/1,000 Base-T Ethernet ports and four 10 GE SFP+ ports, the S5701-28X-LI-24S-AC is dedicated to helping enterprise customers build a reliable and secure next-generation IT network.
Model | S5701-28X-LI-24S-AC |
Part Number | 02357676 |
Fixed Ports | 24 x GE SFP ports |
MAC Address Table Size | 16 MAC |
Voltage Required | AC |
Power Device | AC power supply, supporting RPS |
Power Consumption Operational | < 39.5W |
Forwarding Performance | 96 Mpps |
Switching Capacity | 256 Gbit/s |
Dimensions (W x D x H) | 442 mm x 220 mm x 43.6 mm |
Weight | 4.5 kg |
Note:
(1) | Twenty 100/1000BASE-X ports | (5) | One console port |
(2) | Four combo ports (10/100/1000BASE-T + 100/1000BASE-X) | (6) | One USB port |
(3) | Four 10GE SFP+ ports | (7) | AC socket |
(4) | One mini USB port | (8) | Jack for AC terminal locking latch |
* The AC socket is used with an AC power cable.
* The AC terminal locking latch is not delivered with the switch.
Note:
(1) | Ground screw | (2) | RPS socket |
* The ground screw is used with a ground cable.
* RPS socket is used with an RPS cable, which is not hot swappable.
Model | Description |
10GE SFP+ Optical Transceiver | |
Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC) | |
Optical Transceiver, SFP+, 10G, Single-mode Module (1310nm, 10km, LC) | |
10G Base-USR Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.1km, LC) | |
FE Optical Transceiver | |
Optical Transceiver, SFP, 100M/155M, Multi-mode Module (1310nm, 2km, LC) | |
Optical Transceiver, eSFP, 100M/155M, Single-mode Module (1310nm, 15km, LC) | |
Optical Transceiver, eSFP, FE, Single-mode Module (1310nm, 40km, LC) | |
GE-SFP Optical Transceiver | |
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm, 0.55km, LC) | |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC) | |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 40km, LC) | |
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 40km, LC) | |
GE copper transceiver | |
Electrical Transceiver, SFP, GE, Electrical Interface Module (100m, RJ45) |
Models | S5701-28X-LI-24S-AC | |
Fixed Ports | 24 x 10/100/1,000 Base-T Ethernet ports,4 x 10 GE SFP+ ports | 24 x GE SFP ports, |
Forwarding Performance | 96 Mpps | 96 Mpps |
Switching Capacity | 256 Gbit/s | 256 Gbit/s |
Power Supply | AC power supply, front power sockets, front access | AC power supply, front power sockets, front access |
Power Consumption | < 39.5W | < 60W |
Do you have any question about the S5701-28X-LI-24S-AC (02357676)?
Contact us now via [email protected].
S5701-28X-LI-24S-AC Specification | |
MAC address table | IEEE 802.1d compliance |
MAC address learning and aging | |
Static, dynamic, and blackhole MAC address entries | |
Packet filtering based on source MAC addresses | |
MAC address entries: | |
S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K | |
VLAN | 4K VLANs |
Guest VLAN and voice VLAN | |
GVRP | |
MUX VLAN | |
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | |
1:1 and N:1 VLAN Mapping | |
SuperVLAN (supported by the S5700-SI/S5700-EI/S5700-HI series) | |
Ring protection | RRPP ring topology and RRPP multi-instance |
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover | |
SEP | |
ERPS (G.8032) (supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) | |
STP, RSTP, and MSTP | |
BPDU protection, root protection, and loop protection | |
BPDU Tunnel | |
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) |
ITU-Y.1731 | |
DLDP | |
LACP | |
E-Trunk (supported by the S5700-SI/S5700-EI/S5700-HI series) | |
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) | |
MPLS features | MPLS L3VPN |
MPLS L2VPN(VPWS/VPLS) | |
MPLS-TE | |
MPLS QoS | |
Notes: supported by S5710-EI, S5700-HI and S5710-HI | |
IP routing | Static routing |
RIPv1, RIPv2 and RIPng, ECMP (supported by the S5700-SI/S5700-EI/S5700-HI series) | |
OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) | |
IPv6 features | Neighbor Discovery (ND) |
Path MTU (PMTU) | |
IPv6 ping, IPv6 tracert, and IPv6 Telnet | |
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type | |
MLD v1/v2 snooping | |
6to4 tunnel, ISATAP tunnel, and manually configured tunnel (supported by the S5700-SI/S5700-EI/S5700-HI series) | |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave |
Multicast forwarding in a VLAN and multicast replication between VLANs | |
Multicast load balancing among member ports of a trunk | |
Controllable multicast | |
Port-based multicast traffic statistics | |
IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) | |
QoS/ACL | Rate limiting on packets sent and received by an interface |
Packet redirection | |
Port-based traffic policing and two-rate three-color CAR | |
Eight queues on each port | |
WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms | |
WRED (supported by the S5710-EI and S5700-HI) | |
Re-marking of the 802.1p priority and DSCP priority | |
Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | |
Rate limiting in each queue and traffic shaping on ports | |
Security | User privilege management and password protection |
DoS attack defense, ARP attack defense, and ICMP attack defense | |
Binding of the IP address, MAC address, interface, and VLAN | |
Port isolation, port security, and sticky MAC | |
MFF | |
Blackhole MAC address entries | |
Limit on the number of learned MAC addresses | |
802.1x authentication and limit on the number of users on an interface | |
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC | |
SSH v2.0 | |
Hypertext Transfer Protocol Secure (HTTPS) | |
CPU defense | |
Blacklist and whitelist | |
Access Security | DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |
Management and maintenance | Virtual cable test |
Port mirroring and RSPAN (remote port mirroring) | |
Remote configuration and maintenance using Telnet | |
SNMP v1/v2c/v3 | |
RMON | |
Web NMS | |
HGMP | |
System logs and alarms of different levels | |
802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) | |
Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI (except battery LAN switches) | |
NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) | |
sFlow (supported by the S5700(S)-LI/S5700-EI/S5700-HI series) | |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) |
Supports LNP (Similar to DTP) | |
Supports VCMP (Similar to VTP) | |
Operating environment | Operating temperature: 0°C–50°C |
Input voltage | AC: |
What is Guaranteed.
After receiving your order, take a full month to try it out. If you find quality is not good , we'll take it back and refund your money. Your complete satisfaction is GUARANTEED or your money back. That's guaranteed.
After your order items which are available. We will use most fast delivery way to global countries. Normally we will ship out cargos during 3 -5 days. And international delivery will take about 3- 10 days according to your location.
Service Never Ends.
Hardwares Warrany Time:
Original New Sealed Hardware: 3 Years
Refurbished/Used Original Devices: 1 Year
After warranty time, you also can contact us to return back for repair service. Everything you purchase from HI-NETWORK.COM. We will offer lifetime online service support for your any possible questions.
DELL Used R740 Rack Server
Cisco 9300 24 Port Switch: A Comprehensive Guide
Cisco 9300 Mode Button
Cisco 9300 48 Port Switch: The Definitive Guide
Cisco 9300 IOS Download from Cisco Software Download Center
Cisco Catalyst 9300 Series Switches Setup Guide
Cisco 9300 ROMmon Mode Recovery
Cisco 9300 Power Stack: Understanding Cisco StackPower White paper
Cisco 9300 Stacking Cable Diagram
How to Master Cisco Switch Stacking: Best Practices and Troubleshooting